Figure 19 Composite Airframe Wiring Diagrams

ELT D-SUB

PLUG

CABLE

SHIELD

REMOTE SWITCH

MOLEX PLUG

SHIELD USED AS GROUND WIRE

LIGHT

RESET 1

RESET 2

EXTERNAL ON

G-SWITCH LOOP

G-SWITCH LOOP

GROUND

AUDIO POWER

2

6

13

14

5

12

7

8

8

5

2

7

1

3

6

9

+14V

OR

+28v

UNSWITCHED

POWER

1/2A SLO-BLO FUSE

NOTE: N/C PINS 1, 3, 4,

9, 10, 11, 15.

RED +

BLK –

COMPOSITE AIRFRAME WITH SHIELDED CABLE

ELT D-SUB

PLUG

REMOTE SWITCH

MOLEX PLUG

2

6

13

14

5

12

7

8

8

5

2

7

1

3

6

9

+14V

OR

+28v

UNSWITCHED

POWER

1/2A SLO-BLO FUSE

NOTE: PINS 6 & 9 OF REMOTE

SWITCH ARE INTERNALLY
TIED WITHIN THE REMOTE
SWITCH ASSEMBLY.

NOTE: N/C PINS 1, 3, 4,

9, 10, 11, 15.

RED +

BLK –

COMPOSITE AIRFRAME WITH UNSHIELDED CABLE

PIN INSERTION END OF MOLEX
PLUG FOR REMOTE SWITCH
ASSEMBLY. HOLE NUMBERING
IS IDENTICAL TO THAT INSCRIBED
ON ACTUAL PLUG. ORIENTATION
SHOWN IS SAME AS INSERTION
ORIENTATION FOR INSTALLED
SWITCH.

9

8

7

6

5

4

3

2

1

SOLDER CUP (BACK) SIDE OF D-SUB PLUG
FOR ELT. HOLE NUMBERING IS IDENTICAL
TO THAT INSCRIBED ON ACTUAL PLUG.

NOTE: PINS 6 & 9 OF REMOTE

SWITCH ARE INTERNALLY
TIED WITHIN THE REMOTE
SWITCH ASSEMBLY.

1

9

8

15

LIGHT

RESET 1

RESET 2

EXTERNAL ON

G-SWITCH LOOP

G-SWITCH LOOP

GROUND

AUDIO POWER

AUDIO

INDICATOR

452-6505

AUDIO

INDICATOR

452-6505

Advertising