7. ELT Installation

SUBTASK 25-62-30-410-001

A. Installation and Test

CAUTION:

TAKE CARE TO KEEP THE REMOTE SWITCH PLUG STRAIGHT WHEN CONNECTING IT

TO THE ELT. IF THE PLUG IS COCKED (I.E., CROOKED) WHEN INSERTING IT INTO

THE ELT RECEPTACLE, THE ELT MAY ACTIVATE. IF THE ELT ACTIVATES, RESET IT BY

CYCLING THE LOCAL CONTROL SWITCH TO “ON” AND THEN BACK TO “ARM”.

(1)

See Figure 22 ELT Installation Sequence.

Figure 22 ELT Installation Sequence

(2)

Verify the ELT local switch is in the “ARM” position.

(3)

Insert the ELT into the mounting tray at an angle, such that the locking ears at the end

opposite the direction-of-flight arrow fit into the mounting tray locking slots.

(4)

Press the ELT down until it is fully seated in the mounting tray.

MOUNTING

TRAY ASSY

ELT MAIN

ASSEMBLY

4

3

2

1

CONNECT COAX

CONNECT HARNESS

CLOSE VELCRO STRAP

(STRAP SHOWN IN

CLOSED POSITION)

NOTE: Coax cable and
wiring harness not
shown for clarity.

MOUNTING

TRAY ASSY

ELT MAIN

ASSEMBLY

4

3

2

1

CONNECT COAX

CONNECT HARNESS

CLOSE METAL STRAP

(STRAP SHOWN IN

CLOSED POSITION)

NOTE: Coax cable and
wiring harness not
shown for clarity.