B. remote switch harness fabrication, Figure 20 remote switch harness arrangement – ACR&Artex ME406 HM User Manual

Page 61

Advertising
background image

25-62-30

Page 61 of 84

Jun 25/13

ARTEX PRODUCTS / ACR ELECTRONICS, INC

DESCRIPTION, OPERATION, INSTALLATION AND MAINTENANCE MANUAL

ME406 (453-6603), ME406HM (453-6604)

SUBTASK 25-62-30-450-001

B. Remote Switch Harness Fabrication

(1)

See Figure 20 Remote Switch Harness Arrangement.

Figure 20 Remote Switch Harness Arrangement

(2)

Fabricate a harness long enough to reach from the ELT to the cockpit remote switch, allowing

enough slack to provide a drip loop at the ELT end and a service loop at the cockpit remote

switch end. Refer to the appropriate wiring diagram.

(a)

Strip approximately 0.15 in. (3 mm) of insulation from the remote switch end of each of

the harness cable wires.

(b)

Dress and tin the bare wires to prevent the strands from fraying during terminal

crimping operations.

(3)

Fabricate ground wires as required, based on the wiring diagram appropriate for the

installation.

(4)

Fabricate a power wire long enough to reach from the remote switch plug (Pin 1 or Pin 3) to

the selected aircraft power source.

(5)

Prepare the wires fabricated in Steps (3) and (4), as described in Steps (2)(a) and (2)(b).

(6)

Fabricate two wires, one of sufficient length to reach from the ELT D-Sub connector plug to

the buzzer and the other from the buzzer to ground.

NOTE: These wires provide power and ground for the buzzer. Use appropriate means of

identification for the wires, such that the wires can be readily identified.

PIN 1

PIN 7

PIN 9

PIN 3

151-5009

USE FEMALE

CRIMP PINS

(151-6628)

REMOTE SWITCH (REF.)

REMOTE SWITCH

HARNESS

PIN 1

PIN 9

PIN 8

PIN 15

150-1130

ME406 ELT (REF.)

NOTE: D-SUB HOUSING
NOT SHOWN FOR CLARITY