ARTEX PRODUCTS / ACR ELECTRONICS, INC

DESCRIPTION, OPERATION, INSTALLATION AND MAINTENANCE MANUAL

ME406 (453-6603), ME406HM (453-6604)

25-62-30

Page 38 of 84

Jun 25/13

SUBTASK 25-62-30-750-008

M. Current Draw Test – Item 5f

CAUTION:

EXERCISE EXTREME CAUTION TO AVOID CAUSING A SHORT CIRCUIT CONDITION,

WHICH WILL BLOW THE FUSES IN THE BATTERY PACK. THIS TEST SHOULD ONLY BE

PERFORMED BY AN EXPERIENCED TECHNICIAN/MECHANIC.

CAUTION:

ALL “ON” STATE CURRENT MEASUREMENTS MUST BE MADE WITH THE RF OUTPUT

(I.E., ELT ANTENNA CONNECTOR) LOADED WITH 50 OHMS RATED FOR 5 WATTS.

EITHER A RESISTIVE LOAD OR EQUIPMENT WITH 50 OHM IMPEDANCE PADDED WITH

A 10 DB/5 WATT ATTENUATOR. REFER TO SUBTASK 25-62-30-750-002 ON PAGE 35.

CAUTION:

ACR ELECTRONICS DOES NOT RECOMMEND MEASURING THE 406 MHZ BURST,

WHICH DRAWS UP TO 5 AMPS OF CURRENT; HOWEVER, THE AMMETER USED TO

MEASURE THE STEADY STATE CURRENT OF THE 121.5 MHZ TRANSMISSION MUST BE

CAPABLE OF WITHSTANDING A 5 AMP CURRENT DRAW OR MUST HAVE THE READING

SCALE ADJUSTED ACCORDINGLY. KEEP IN MIND THE ELT TRANSMITS A 406 MHZ

BURST WHEN THE ELT IS RESET, IN ADDITION TO A 406 MHZ BURST

APPROXIMATELY EVERY 50 SECONDS.

(1)

Verify the ELT control switch is in the “ARM” position.

Separate the battery pack from the ELT. See SUBTASK 25-62-30-050-001 on page 46

(2)

Install test fixture 500-0057 in the power circuit. See Figure 9 Current Draw Test Setup.

Figure 9 Current Draw Test Setup

(3)

Connect the ammeter and set it for the lowest possible scale.

(4)

Read the current draw on the ammeter. Measured current must be £ 2 µA (micro-amps).

TEST FIXTURE
500-0057

CONNECT ELT FLEX

CABLE HERE

CONNECT TEST FIXTURE

TO BATTERY PACK PLUG

+