Battery pack installation, A. battery reinstallation, Figure 24 battery pack installation – ACR&Artex ME406 HM User Manual

Page 71: Subtask 25-62-30

Advertising
background image

25-62-30

Page 71 of 84

Jun 25/13

ARTEX PRODUCTS / ACR ELECTRONICS, INC

DESCRIPTION, OPERATION, INSTALLATION AND MAINTENANCE MANUAL

ME406 (453-6603), ME406HM (453-6604)

TASK 25-62-30-450-806

8. Battery Pack Installation

SUBTASK 25-62-30-450-001

A. Battery Reinstallation

CAUTION:

THE BATTERY PACK CONTAINS ELECTROSTATIC DISCHARGE SENSITIVE (ESD)

COMPONENTS AND IT MUST BE HANDLED WITH CARE. IF POSSIBLE, WEAR A

GROUNDED WRIST STRAP WHEN HANDLING THE BATTERY PACK DURING

INSTALLATION ACTIVITIES. TAKE PARTICULAR CARE TO AVOID TOUCHING THE

EXPOSED CIRCUIT BOARD AND CONNECTOR PINS ON THE BOARD.

(1)

This subtask applies to reinstallation of an existing battery that was removed for inspection

and testing.

(2)

See Figure 24 Battery Pack Installation.

Figure 24 Battery Pack Installation

(3)

Verify the gasket is in place and in good condition.

(4)

Lay the battery pack on the work surface with the cells facing up.

(5)

Align the ELT with the battery pack, holding it slightly above the pack with one hand.

(6)

Connect the ELT flex cable receptacle to the plug on the battery pack circuit board using the

other hand, taking care not to put a twist in the flex cable.

NOTE: The receptacle should “click” into place when properly mated to the plug.

SCREW P/N 201-0402

(8 PLCS)

GASKET

ELT ASSEMBLY

BATTERY PACK

CONNECT

(ELT flex cable not

shown for clarity)

Advertising