Figure 8. me406p portable configuration, E. elt reset, F. functional check – ACR&Artex ME406 Portable ELT User Manual

Page 28: Figure 8, Me406p portable configuration

Advertising
background image

ARTEX PRODUCTS / ACR ELECTRONICS, INC

DESCRIPTION, OPERATION, INSTALLATION AND MAINTENANCE MANUAL

ME406P (453-6611)

25-62-31

Page 28 of 85

JUN 25/13

(7)

A tether assembly is attached to the ELT; however, the ELT is not buoyant on its own and a

flotation device is required for deployment in water.

Figure 8. ME406P Portable Configuration

SUBTASK 25-62-31-870-005

E.

ELT Reset

(1)

If the ELT is activated accidently, it will need to be reset.

(2)

Reset the ELT from the cockpit by moving the remote switch to the “ON” position, waiting

approximately one second, and then moving it back to the “ARM” position. If the switch is

already in the “ON” position, move it to the “ARM” position.

(3)

Reset the ELT locally by moving the switch on the ELT to the “ON” position, waiting

approximately one second, and then moving it back to the “ARM” position. If the switch is

already in the “ON” position, move it to the “ARM” position.

NOTE: The ELT cannot be reset if either the cockpit remote switch or the ELT local switch is

in the “ON” position.

SUBTASK 25-62-31-750-001

F.

Functional Check

(1)

A monthly functional check is recommended to verify operational status of the ELT.

(2)

Perform this functional check in accordance with SUBTASK 25-62-31-750-011 on page 41.

TETHER

ASSEMBLY

ME406P

PORTABLE

ANTENNA

STATUS

LED

CONTROL

SWITCH

ANTENNA BNC

CONNECTOR

FRONT VIEW

Advertising