ACR&Artex ME406 Portable ELT User Manual

Page 64

Advertising
background image

ARTEX PRODUCTS / ACR ELECTRONICS, INC

DESCRIPTION, OPERATION, INSTALLATION AND MAINTENANCE MANUAL

ME406P (453-6611)

25-62-31

Page 64 of 85

JUN 25/13

(3)

Slide the grommet away from the cable and other conductor ends, such that it does not

interfere with soldering the conductors to the plug (150-1130).

(4)

Solder the buzzer ground conductor to the cable shield or ground conductor for composite

airframe installations. See Figure 20. Composite Airframe Wiring Diagrams on page 61.

(5)

Fabricate a short jumper wire, approximately 1.5 in. (38 mm) long.

CAUTION:

THE ELT WILL NOT AUTOMATICALLY ACTIVATE IF THE JUMPER (G-SWITCH

LOOP) IS NOT PROPERLY INSTALLED IN THE ELT D-SUB CONNECTOR.

(a)

Strip approximately 0.15 in. (3 mm) of insulation from both ends of each of the wire.

(b)

Dress and tin the bare wire ends to prevent the strands from fraying during terminal

crimping operations.

(c)

Solder the jumper wire to D-Sub pins 5 and 12.

(6)

Solder the wiring to the D-Sub plug as follows, referring to the wiring diagram appropriate for

the installation:

(a)

Harness wires,

NOTE: Make note of the wiring identification and pin location relationships, such that

the wiring at the remote switch end can be terminated correctly.

(b)

Buzzer power wire, and

(c)

Ground wire.

(7)

Fit the plug into a housing half positioning the grommet such that it fits into the recess on the

cable end of the housing, with the raised collar step against the housing inside face.

(8)

Install the bracket washers onto the thumbscrews.

(9)

Insert thumbscrews into lower housing half.

(10) Fit the other housing half into place.

(11) Screw housing halves together using the screws and nuts supplied as part of the housing kit.

Advertising