Operation, A. operational overview, Figure 6. elt operational flow diagram – ACR&Artex G406-4 ELT User Manual

Page 31

Advertising
background image

25-62-21

Page 31 of 86

JUL 31/12

ACR ELECTRONICS, INC / ARTEX PRODUCTS

DESCRIPTION, OPERATION, INSTALLATION AND MAINTENANCE MANUAL

G406-4 (453-5012)

TASK 25-62-21-870-802

2. Operation

SUBTASK 25-62-21-870-001

A. Operational Overview

(1)

See "Figure 6. ELT Operational Flow Diagram".

(2)

A primary feature of the G406-4 ELT is its simplicity of operation. As long as the ELT is

connected to the remote switch harness ELT connector, such that pins 5 and 8 are jumpered

(G-switch loop), it will activate in the event of a crash.

NOTE: Neither the cockpit remote switch or the ELT local switch can be positioned in such a

manner as to prevent automatic activation when the ELT is connected properly.

Figure 6. ELT Operational Flow Diagram

(3)

ELT operation is designed to prevent human error and misuse in regards to automatic

activation. The ELT cannot be activated by dropping, rough handling or during shipping.

(4)

When the ELT is activated, the presence of the emergency sweep tone and the flashing

cockpit remote switch panel LED indicates an active, normal functioning ELT. The cockpit

panel LED must immediately begin to flash continuously upon ELT activation.

(5)

The ELT is considered to be either “ACTIVE” or “INACTIVE”. When “INACTIVE”, the ELT is in a

state of rest and performs no functions. Taking the ELT from the “INACTIVE” state to the

“ACTIVE” state requires a positive switch transition from either the cockpit remote switch, ELT

local switch, or G-switch.

ELT

“INACTIVE”

ELT “ACTIVE”

BUZZER “ON”

LED “ON”

ELT

SWITCH

“ON”

REMOTE

SWITCH

“ON”

G-SWITCH

“ON”

ELT OR

REMOTE SW

“RESET”

YES

YES

NO

NO

NO

YES

NO

YES