DESCRIPTION, OPERATION, INSTALLATION AND MAINTENANCE MANUAL

G406-4 (453-5012)

25-62-21

Page 64 of 86

JUL 31/12

TASK 25-62-21-450-805

6. Wiring

SUBTASK 25-62-21-990-001

A. General Considerations and Recommendations

CAUTION:

IF GROUND OR OTHER CONNECTIONS ARE BROKEN OR OTHERWISE DAMAGED, THE

ELT IS STILL CAPABLE OF AUTOMATIC ACTIVATION; HOWEVER, THE COCKPIT

REMOTE SWITCH MAY BE INCAPABLE OF RESETTING THE ELT AND OPERATION MAY

NOT BE INDICATED ON THE REMOTE SWITCH LED.

CAUTION:

INCORRECT TERMINATION OF THE WIRING IN THE CONNECTORS MAY DAMAGE THE

ELT, CAUSE TRANSMISSION ISSUES, OR RESULT IN A NON-FUNCTIONING REMOTE

SWITCH. VERIFY THE WIRING AGAINST THE WIRING DIAGRAM AND PERFORM A

CONTINUITY CHECK TO CONFIRM GOOD CONNECTIONS AND PROPER PIN

LOCATIONS.

CAUTION:

TO PREVENT INADVERTENT ELT ACTIVATION OR POSSIBLE COMPONENT DAMAGE,

DO NOT CONNECT THE HARNESS TO THE ELT OR COCKPIT REMOTE SWITCH UNTIL

ALL POWER AND GROUND WIRING CONNECTIONS ARE COMPLETED.

(1)

The following wiring and grounding considerations and recommendations are applicable:

(a)

Minimum 22 AWG wire size.

(b)

Shielding is recommended to help prevent EMI and RF interference.

(c)

Use high quality conductor meeting MIL-W-16878, M22759, M27500, or a commercial

equivalent acceptable for use in aircraft applications.

(d)

Provide a “Drip Loop” in the remote switch harness connection to the ELT to divert

moisture from the connector. See TASK 25-62-21-990-805, on page 21, for a definition.

(e)

Provide a “Service Loop” in the remote switch harness connection to the remote switch

assembly, such that the assembly can be withdrawn from the panel far enough to easily

disconnect the harness plug. See TASK 25-62-21-990-805, on page 21, for a definition.

(f)

ELT and remote switch grounds must be common to aircraft ground.