3. Specifications

SUBTASK 25-62-21-870-001

A. Environmental and Physical

(1)

Table 2 lists the environmental and physical specifications of the G406-4 ELT.

NOTE: For automatic activation, the higher threshold of 4.5 ft/sec (2.3

g

) is specified in

accordance with Eurocae ED-62. Use of the higher threshold crash sensor has been

approved by the FAA as a deviation to TSO C126 (FAA Reference #98-130S-108,

February 6, 1998).

Table 2. Environmental and Physical Specifications

CRITERIA

PARAMETER

CHARACTERISTIC

Temperature

Storage

-55° C to +85° C

Operating

-20° C to +55° C

Mechanical

Vibration

10

g

, 5 Hz to 2,000 Hz

Shock

500

g

for 4 ms

Crashworthiness

100

g

for 23 ms

Humidity

95% for 50 hours

Penetration

55 lbs from 6 in. (25 kg from 15 cm)

Crush

1,000 lbs (454 kg)

Altitude

55,000 ft (16,764 m)

Automatic Activation

G-Switch

4.5 ±0.5 ft/sec (2.3

g

)

Weight

ELT Complete w/Battery Pack,

Mounting Tray, and Covers

4.25 lbs (1.9 kg)

Dimensions (LxHxW)

ELT Complete w/Battery Pack,

Mounting Tray, and Covers

11.63 x 3.90 x 3.76 in.

(295 x 99 x 96 mm)

Software

In accordance with RTCA/DO-178B, Level D