Figure 19. remote switch harness wiring diagram – ACR&Artex G406-4 ELT User Manual

Page 66

Advertising
background image

ACR ELECTRONICS, INC / ARTEX PRODUCTS

DESCRIPTION, OPERATION, INSTALLATION AND MAINTENANCE MANUAL

G406-4 (453-5012)

25-62-21

Page 66 of 86

JUL 31/12

be spliced in a manner acceptable to the aircraft manufacturer, or as described

in AC 43.13-1, Paragraph 11-167.

(b)

Fabricate ground wire long enough to reach from Pin 9 of the remote switch plug to

aircraft ground.

(c)

Fabricate a power wire long enough to reach from the remote switch plug (Pin 1 or Pin

3) to the selected aircraft power source.

(d)

Prepare the wires as described in Steps (3)(a) and (3)(b).

Figure 19. Remote Switch Harness Wiring Diagram

(4)

Fabricate two wires of sufficient length to reach from the harness ELT receptacle to the

buzzer.

NOTE: These wires provide power and ground for the buzzer. Use appropriate means of

identification for the wires, such that the wires can be readily identified.

(a)

Prepare the wires as described in Steps (3)(a) and (3)(b).

(5)

Crimp male terminal pins (151-6627) on the harness wire ends at the ELT, as follows:

NOTE: Use Molex crimp tool 63811-3300, or an equivalent tool for 0.062 in. terminal pins.

(a)

The ground wire in the same pin as the harness wire designated to terminate in Pin 11.

Make a note of the wire identification for later reference.

(b)

On each of the remaining wire ends at the harness ELT end.

(c)

The buzzer power and ground wires.

LIGHT

RESET 1
RESET 2

EXTERNAL ON

G-SWITCH LOOP
G-SWITCH LOOP

GROUND

HORN POWER

HORN GROUND

1

3

6

7

12

5
8

9

10
11

2
4

8

5

2

7

1

3

6

9

+14 VDC

+28 VDC

ELT

RECEPTACLE

COCKPIT REMOTE

SWITCH PLUG

PIN INSERTION END VEIW
OF MOLEX RECEPTACLE FOR ELT.
HOLE NUMBERING IS IDENTICAL
TO THAT INSCRIBED ON ACTUAL
RECEPTACLE. ORIENTATION
SHOWN IS SAME AS INSERTION
ORIENTATION FOR ELT.

PIN INSERTION END OF MOLEX
PLUG FOR REMOTE SWITCH
ASSEMBLY. HOLE NUMBERING
IS IDENTICAL TO THAT INSCRIBED
ON ACTUAL PLUG. ORIENTATION
SHOWN IS SAME AS INSERTION
ORIENTATION FOR INSTALLED
SWITCH.

HORN

APPLY EITHER +14 V TO PIN 1 OR
+28 V TO PIN 3, BUT NOT BOTH

NOTE: BYPASS THE AIRCRAFT
AND AVIONICS MASTER SWITCHES.
CONNECT POWER DIRECTLY TO
BATTERY WITH A 1-AMP IN-LINE
FUSE OR CONNECT TO AIRCRAFT
CLOCK CIRCUITRY. MAXIMUM
CIRREMT REQUIRED IS ABOUT
100 mA. CIRCUIT MUST BE FUSED.

NOTE: PINS 6 AND 9 OF REMOTE SWITCH ARE
INTERNALLY TIED. IF AIRCRAFT GROUND
INTEGRITY BETWEEN THE ELT AND REMOTE
SWITCH CANNOT BE GUARANTEED, THEN
REMOTE SWITCH PIN 6 IS WIRED TO ELT PIN 11,
OTHERWISE THE CONNECTION IS OPTIONAL.

USE MINIMUM

22 AWG WIRE

9

8

7

6

5

4

3

2

1

3

2

1

4

7

5

8

6

9

10

11

12

Advertising