Mounting tray, A. location, Figure 12. g406-4 elt outline and dimensions – ACR&Artex G406-4 ELT User Manual

Page 57

Advertising
background image

25-62-21

Page 57 of 86

JUL 31/12

ACR ELECTRONICS, INC / ARTEX PRODUCTS

DESCRIPTION, OPERATION, INSTALLATION AND MAINTENANCE MANUAL

G406-4 (453-5012)

TASK 25-62-21-450-801

2. Mounting Tray

SUBTASK 25-62-21-450-001

A. Location

CAUTION:

MANY ORIGINAL ELT INSTALLATIONS ARE INADEQUATE AS FAR AS UNIT LOCATION

AND SURFACE RIGIDITY ARE CONCERNED. BECAUSE OF THE CRITICAL FUNCTION AN

ELT PERFORMS, IT IS IMPORTANT THE INSTALLATION FOLLOWS THE INSTRUCTIONS

AND RECOMMENDATIONS HEREIN.

CAUTION:

THE MOUNTING SURFACE MUST BE EXTREMELY RIGID; THEREFORE, MOUNTING AN

ELT DIRECTLY TO THE AIRCRAFT SKIN IS UNACCEPTABLE. MOUNTING THE ELT

DIRECTLY TO THE AIRCRAFT SKIN INDUCES “CRASH HIDING” VIBRATIONS AND

PROVIDES A VERY POOR MOUNTING SURFACE.

CAUTION:

AVOID LOCATING THE ELT WHERE IT WILL BE SUBJECTED TO UNPROTECTED

EXPOSURE TO HARSH CHEMICAL FLUIDS SUCH AS DEICING COMPOUNDS. THESE

TYPES OF CHEMICAL FLUIDS CAN PROMOTE CRACKING AND FRACTURING OF THE

ELT MOUNTING FRAME AND HOUSING COMPONENTS BY DEGRADING THE

STRUCTURAL INTEGRITY OF THESE COMPONENTS. THESE SAME CHEMICAL AGENTS

MAY ALSO CAUSE CORROSION OF ELECTRICAL CONNECTIONS.

(1)

Select a suitable location for the ELT mounting tray. See "Figure 12. G406-4 ELT Outline and

Dimensions". Refer to these dimensions when determining mounting location.

Figure 12. G406-4 ELT Outline and Dimensions

FLIGHT

5.21

(132)

1.71
(43)

11.63

(295)

5.50

(140)

3.42

(87)

2.00

(51)

3.76
(96)

3.90

(99)

0.17 (4) Ø MOUNTING

HOLES (4 PLCS)

Dimensions in inches (mm)

NOTE: Allow a minimum of
5 inches (127 mm) of clearance
in front of the mounting frame cap
to facilitate cap removal.