Figure 7. performance testing equipment setup, H. 121.5 mhz frequency measurement – item 5a, I. audio modulation check – item 5b – ACR&Artex G406-4 ELT User Manual

Page 42

Advertising
background image

ACR ELECTRONICS, INC / ARTEX PRODUCTS

DESCRIPTION, OPERATION, INSTALLATION AND MAINTENANCE MANUAL

G406-4 (453-5012)

25-62-21

Page 42 of 86

JUL 31/12

(1)

Place the ELT in a container or screen room capable of substantially attenuating RF signals, or

the transmitter power output shall be connected to a suitable dummy load to minimize

radiation.

(2)

Use the ELT’s own battery pack as the power source for these measurements. An alternate

power source can be used where lengthy servicing, other than the performance tests, is

anticipated.

(3)

Ensure that adequate attenuation rated for 406 MHz is installed between the ELT antenna

output and the measurement equipment to prevent damaging input circuitry, if required. At a

minimum, the attenuator should be rated at 30 dB, and 5 watts for a ½-second duration. As

shown in "Figure 7. Performance Testing Equipment Setup".

Figure 7. Performance Testing Equipment Setup

SUBTASK 25-62-21-750-003

H. 121.5 MHz Frequency Measurement – Item 5a

(1)

Connect the measuring device, referring to SUBTASK 25-62-21-750-002, on page 41.

(2)

Activate the ELT by placing the control switch in the “ON” position.

(3)

Wait three minutes.

(4)

Perform SUBTASK 25-62-21-750-004 during the three-minute waiting period.

(5)

Measure the frequency after the three-minute waiting period. The frequency must be within

the tolerance specified in Table 3, on page 34.

NOTE: If the 121.5 MHz carrier frequency is within specified tolerance, the 243.0 MHz

frequency will also be within tolerance.

SUBTASK 25-62-21-750-004

I.

Audio Modulation Check – Item 5b

(1)

Perform this check in conjunction with SUBTASK 25-62-21-750-003.

(2)

Monitor 121.5 MHz on an AM receiver.

(3)

Listen for the aural sweep tone on the receiver. The audio should “sound” like an ELT.

ELT ANTENNA

BNC CONNECTOR

(121.5/243.0 MHz)

TPS CONNECTOR

(406 MHz)

30 dB

ATTENUATOR

(if required)

MEASURING

DEVICE

Advertising