M. current draw test – item 5f, Figure 8. current draw test setup – ACR&Artex G406-4 ELT User Manual

Page 44

Advertising
background image

ACR ELECTRONICS, INC / ARTEX PRODUCTS

DESCRIPTION, OPERATION, INSTALLATION AND MAINTENANCE MANUAL

G406-4 (453-5012)

25-62-21

Page 44 of 86

JUL 31/12

SUBTASK 25-62-21-750-008

M. Current Draw Test – Item 5f

CAUTION:

EXERCISE EXTREME CAUTION TO AVOID CAUSING A SHORT CIRCUIT CONDITION,

WHICH WILL BLOW THE FUSES IN THE BATTERY PACK. THIS TEST SHOULD ONLY BE

PERFORMED BY AN EXPERIENCED TECHNICIAN/MECHANIC.

CAUTION:

ALL “ON” STATE CURRENT MEASUREMENTS MUST BE MADE WITH THE RF OUTPUT

(I.E., ELT ANTENNA CONNECTOR) LOADED WITH 50 OHMS RATED FOR 5 WATTS.

EITHER A RESISTIVE LOAD OR EQUIPMENT WITH 50 OHM IMPEDANCE PADDED WITH

10 DB/5 WATT ATTENUATOR. REFER TO SUBTASK 25-62-21-750-002, ON PAGE 41.

(1)

Verify the ELT control switch is in the “OFF” position.

(2)

Separate the battery pack from the ELT.

(3)

Disconnect the 2-wire ELT power connector.

(4)

Install test harness 611-0024, or equivalent, in the power circuit. See "Figure 8. Current Draw

Test Setup".

Figure 8. Current Draw Test Setup

(5)

Read the current draw on the ammeter. Measured current should be 0 µA (micro-amps), and

must not be more than 6 µA.

(6)

Verify the ammeter is set to accommodate a range of at least 3.5 amps.

(7)

Activate the ELT by placing the control switch in the “ON” position.

+

A

CIRCUIT BOARD IN

BATTERY PACK

TO ELT

611-0024

TEST HARNESS

Advertising