Page 11 of 60

Offset

Field

Size

Value

Description

40

dwFeatures

4

000204B0h

ACR33U-A1 supports the following

features:
Automatic ICC clock frequency change

according to parameters
Automatic baud rate change according

to frequency and FI,DI parameters
Automatic PPS made by the CCID

according to the active parameters
Automatic IFSD exchange as first

exchange (T=1 protocol in use)
Short APDU level exchange with CCID

44

dwMaxCCIDMessageLength

4

0000010Fh Maximum message length accepted by

ACR33U-A1 is 271 bytes

48

bClassGetResponse

1

00h

Insignificant for TPDU level exchanges

49

bClassEnvelope

1

00h

Insignificant for TPDU level exchanges

50

wLCDLayout

2

0000h

No LCD

52

bPINSupport

1

03h

With PIN Verification and Modification

53

bMaxCCIDBusySlots

1

01h

Only 1 slot can be simultaneously busy