Page 34 of 60

P2 =

0000

00rp

b

where the two bits “rp” indicate the password to compare

r = 0: Write password,
r = 1: Read password,
p = Password set number,
rp = 01 for the secure code


Response data format (abData field in the RDR_to_PC_DataBlock)

SW1

SW2

ErrorCnt

90h

Where:

SW1

= 90h

SW2 (ErrorCnt) = Error Counter. FFh indicates the verification is correct. 00h indicates the

password is locked (exceeded the maximum number of retries). Other

values indicate the current verification has failed.

8.3.3.5. INITIALIZE_AUTHENTICATION

Command format (abData field in the PC_to_RDR_XfrBlock)

Pseudo-APDU

CLA INS P1 P2 Lc Q(0) Q(1) … Q(7)

FFh 84h 00h 00h 08h

Where:

Q(0),Q(1)…Q(7): Host random number, 8 bytes


Response data format (abData field in the RDR_to_PC_DataBlock)

SW1 SW2

Where:

SW1, SW2 = 90 00h if no error

8.3.3.6. VERIFY_AUTHENTICATION

Command format (abData field in the PC_to_RDR_XfrBlock)

Pseudo-APDU

CLA INS P1 P2 Lc Ch(0) Ch(1) … Ch(7)

FFh 82h 00h 00h 08h