8.2.3.

RDR_to_PC_Parameters

This message is sent by ACR33U-A1 in response to PC_to_RDR_GetParameters and

PC_to_RDR_SetParameters messages.

Offset

Field

Size

Value Description

0

bMessageType

1

82h

-

1

dwLength

4

-

Size of extra bytes of this message

5

bSlot

1

-

Same value as in Bulk-OUT message

6

bSeq

1

-

Same value as in Bulk-OUT message

7

bStatus

1

-

Slot status register as defined in CCID

Section 4.2.1

8

bError

1

-

Slot error register as defined in CCID

Section 4.2.1

9

bProtocolNum

1

-

Specifies what protocol data structure

follows:
00h = Structure for protocol T=0
01h = Structure for protocol T=1
The following values are reserved for

future use.
80h = Structure for 2-wire protocol
81h = Structure for 3-wire protocol
82h = Structure for I2C protocol

10

abProtocolDataSt

ructure

Byte

array

-

Protocol Data Structure as summarized

in CCID Section 10.1.6


Protocol Data Structure for Protocol T=0 (bProtocolNum=0, dwLength=00000005h)

Offset

Field

Size Value Description

10

bmFindexDindex

1

-

B7-4 – FI – Index into the Table 7 in

ISO/IEC 7816-3:1997 selecting a clock

rate conversion factor
B3-0 – DI - Index into the Table 8 in
ISO/IEC 7816-3:1997 selecting a baud

rate conversion factor

11

bmTCCKST0

1

00h,

02h

For T=0, B0 – 0b, B7-2 – 000000b
B1 – Convention used (b1=0 for direct,

b1=1 for inverse)

12

bGuardTimeT0

1

00-FFh

Extra guard time between two

characters. Add 0 to 254etu to the

normal guard time of 12etu. FFh is the

same as 00h.

13

bWaitingIntegerT0

1

00-FFh WI for T=0 used to define WWT