Pc_to_rdr_escape, Buzzer – ACS ACR33U-A1 SmartDuo Smart Card Reader User Manual

Page 19

Advertising
background image

ACR33U-A1 – Reference Manual

[email protected]

Version 1.02

www.acs.com.hk

Page 19 of 60

8.1.7.

PC_to_RDR_Escape

Defines and access extended features.

Offset

Field

Size

Value Description

0

bMessageType

1

6Bh

-

1

dwLength

4

-

Size of abData field of this message

5

bSlot

1

00-05h Identifies the slot number for this

command

6

bSeq

1

00-FFh Sequence number for command

7

abRFU

3

-

Reserved for future use

10

abData

Byte

array

-

Data block sent to the CCID

8.1.7.1. LED

Offset

Field

Size

Value Description

10

bcmdCode

1

01h

-

11

wcmdLength

2

0001h

-

13

abRFU

2

-

Reserved for future use

15

abData

1

00000

XYZb

00000xxx for 3 LED,
XYZ: 000 => 3 LEDs off
XYZ: 001 => LED1 on, green for 1 Sec
XYZ: 010 => LED2 on, red for 1 Sec
XYZ: 100 => LED3 on, blue for 1 Sec


The response to this command message is the RDR_to_PC_Escape

response message.

8.1.7.2. BUZZER

Offset

Field

Size

Value Description

10

bcmdCode

1

08h

-

11

wcmdLength

2

0001h

-

13

abRFU

2

-

Reserved for future use

15

abData

1

XXh

XX for buzzer on or off,
YZ: 5A = buzzer on for 1 Sec
YZ: A5 = buzzer off


The response to this command message is the RDR_to_PC_Escape response message.

Advertising