Commands, Ccid command pipe bulk-out messages, Pc_to_rdr_iccpoweron – ACS ACR33U-A1 SmartDuo Smart Card Reader User Manual

Page 12

Advertising
background image

ACR33U-A1 – Reference Manual

[email protected]

Version 1.02

www.acs.com.hk

Page 12 of 60

8.0. Commands

8.1. CCID Command Pipe Bulk-OUT Messages

ACR33U-A1 shall follow the CCID Bulk-OUT Messages as specified in CCID Section 4. In addition,

this specification defines some extended commands for operating additional features.
This section lists the CCID Bulk-OUT Messages to be supported by ACR33U-A1.

8.1.1.

PC_to_RDR_IccPowerOn

Activates the card slot and return ATR from the card.

Offset

Field

Size

Value

Description

0

bMessageType

1

62h

-

1

dwLength

4

00000000h Size of extra bytes of this message

2

bSlot

1

00-05h

Identifies the slot number for this

command

5

bSeq

1

00-FFh

Sequence number for command

6

bPowerSelect

1

01h

Voltage that is applied to the ICC:
01h – 5 volts

7

abRFU

2

-

Reserved for future use


The response to this command message is the RDR_to_PC_DataBlock response message and the

data returned is the Answer-to-Reset (ATR) data.