Pc_to_rdr_setparameters – ACS ACR33U-A1 SmartDuo Smart Card Reader User Manual

Page 17

Advertising
background image

ACR33U-A1 – Reference Manual

[email protected]

Version 1.02

www.acs.com.hk

Page 17 of 60

8.1.6.

PC_to_RDR_SetParameters

Sets slot parameters.

Offset

Field

Size

Value Description

0

bMessageType

1

61h

-

1

dwLength

4

-

Size of extra bytes of this message

5

bSlot

1

00-05h Identifies the slot number for this

command

6

bSeq

1

00-FFh Sequence number for command

7

bProtocolNum

1

00h,

01h

Specifies what protocol data structure

follows.
00h = Structure for protocol T=0
01h = Structure for protocol T=1
The following values are reserved for

future use:
80h = Structure for 2-wire protocol
81h = Structure for 3-wire protocol
82h = Structure for I2C protocol

8

abRFU

2

-

Reserved for future use

10

abProtocolDataStructure Byte

array

-

Protocol Data Structure


The response to this message is the RDR_to_PC_Parameters message.

Protocol Data Structure for Protocol T=0 (dwLength=00000005h)

Offset

Field

Size Value Description

10

bmFindexDindex

1

-

B7-4 – FI – Index into the Table 7 in

ISO/IEC 7816-3:1997 selecting a clock

rate conversion factor
B3-0 – DI - Index into the Table 8 in
ISO/IEC 7816-3:1997 selecting a baud

rate conversion factor

11

bmTCCKST0

1

-

B0 – 0b, B7-2 – 000000b
B1 – Convention used (b1=0 for direct,

b1=1 for inverse) Note: The CCID

ignores this bit.

12

bGuardTimeT0

1

00-FFh

Extra guard time between two

characters. Add 0 to 254etu to the

normal guard time of 12etu. FFh is the

same as 00h.

13

bWaitingIntegerT0

1

00-FFh WI for T=0 used to define WWT

Advertising