Setup linear error compensation – ACU-RITE Micro-Line T User Manual

Page 10

Advertising
background image

MICRO-LINE

Reference Manual

7

SETUP

Linear Error Compensation

With

MICRO-LINE

, you can compensate for machine tool wear. If you

know the linear error compensation (LEC) value in parts-per-million
(PPM), you can enter it directly.

If you don’t know the LEC, use the formula on the next page to determine
the value for each axis.

Move to the “Linear Error Compensation” display in the Setup
mode. (Press SETUP and then the ENTER key until “LEC”
appears).

Press the

X

or

Z

key for the axis you want to change.

MICRO-LINE

will display the current LEC value for that axis.

Using the keypad, enter the linear error compensation factor
(in PPM), followed by the ± key for negative values. The number
must be within -9999 and 9999 (use whole numbers). The formula for

calculating the value is on the next page.

After you complete setting your LEC, press ENTER to
continue with setup or press ENTER then SETUP to return to the
normal DRO display.

To change the linear error compensation: