Assembly – Bosch GMF 1600 CE Professional User Manual

Page 21

Advertising
background image

English | 21

Bosch Power Tools

2 610 022 197 | (9.2.12)

Technical Data

Noise/Vibration Information

Measured sound values determined according to EN 60745.
Typically the A-weighted noise levels of the product are: Sound pressure level 86 dB(A); Sound power level 97 dB(A). Uncer-

tainty K =3 dB.

Wear hearing protection!

The vibration emission level given in this information sheet

has been measured in accordance with a standardised test

given in EN 60745 and may be used to compare one tool with

another. It may be used for a preliminary assessment of expo-

sure.

The declared vibration emission level represents the main ap-

plications of the tool. However if the tool is used for different

applications, with different accessories or poorly maintained,

the vibration emission may differ. This may significantly in-

crease the exposure level over the total working period.

An estimation of the level of exposure to vibration should also

take into account the times when the tool is switched off or

when it is running but not actually doing the job. This may sig-

nificantly reduce the exposure level over the total working pe-

riod.

Identify additional safety measures to protect the operator

from the effects of vibration such as: maintain the tool and the

accessories, keep hands warm, organise work patterns.

Declaration of Conformity

We declare under our sole responsibility that the product de-

scribed under “Technical Data” is in conformity with the fol-

lowing standards or standardization documents: EN 60745

according to the provisions of the directives 2011/65/EU,

2004/108/EC, 2006/42/EC.

Technical file (2006/42/EC) at:

Robert Bosch GmbH, PT/ETM9,

D-70745 Leinfelden-Echterdingen

Robert Bosch GmbH, Power Tools Division

D-70745 Leinfelden-Echterdingen

25.01.2012

Assembly

f

Before any work on the machine itself, pull the mains

plug.

Inserting the Routing Motor into the Plunge

Base/Non-plunge Base (see figures A–B)

– Open the clamping lever for the plunge base/non-plunge

base 22.

– Push the routing motor to the stop into the plunge base/

non-plunge base.

– When using the non-plunge base 3, press clamping lever

25 and slide the routing motor 1 up or down to the desired

Multifunction Router

GOF 1600 CE

GMF 1600 CE

Article number

3 601 F24 0..

3 601 F24 0..

Rated power input

W

1600

1600

No-load speed

min

-1

10000 – 25000

10000 – 25000

Speed preselection

z

z

Constant electronic control

z

z

Connection for dust extraction

z

z

Tool holder

mm

inch

8 – 12

¼ – ½

8 – 12

¼ – ½

Plunge depth (plunge base)

mm

76

76

Weight according to EPTA-Procedure 01/2003

– Contour router

– Plunge router

kg

kg

5.8

4.3

5.8

Protection class

/II

/II

The values given are valid for a nominal voltage [U] of 230 V. For different voltages and models for specific countries, these values can vary.

Routing with

Non-plunge Base

Routing with

Plunge Base

Vibration total values a

h

(triax vector sum) and uncertainty K determined

according to EN 60745:

a

h

K

m/s

2

m/s

2

=6.0

=1.5

=5.5

=1.5

Dr. Egbert Schneider

Senior Vice President

Engineering

Dr. Eckerhard Strötgen

Engineering Director

PT/ESI