Audible and visual alarms – SUUNTO Cobra User Manual

Page 37

Advertising
background image

35

3.7. AUDIBLE AND VISUAL ALARMS

The dive computer features audible and visual alarms to advise when important
limits are approached or to acknowledge preset alarms.

A short single beep occurs, when:

the dive computer is activated.

when the dive computer automatically returns to the TIME mode.

Three double beeps occur, when:

the cylinder pressure reaches 50 bar [725 psi]. The cylinder pressure

display will start to blink (Fig. 3.12.).

the cylinder pressure reaches 35 bar [500 psi].

the calculated remaining air time reaches zero.

Three single beeps with a two second interval and the backlight activated for
5 seconds occur, when:

the no-decompression dive turns into a decompression stop dive. An

arrow pointing upwards and the blinking ascent warning ASC TIME
will appear (Fig. 3.16.).

Continuous beeps and the backlight activated for 5 seconds occur, when:

the maximum allowed ascent rate, 10 m/min [33 ft/min], is exceeded.

SLOW and STOP warnings will appear (Fig. 3.13.).

the Mandatory Safety Stop ceiling is exceeded. A downward pointing

arrow will appear (Fig. 3.15.).

the decompression ceiling depth is exceeded. An error warning Er and a

downward pointing arrow appear. You should immediately descend to,
or below, the ceiling. The instrument will otherwise enter a permanent
Error Mode within three minutes, indicated by a permanent Er (Fig.
3.19.).

Advertising