Air shifter valve – Spicer Tandem Drive Axle Dual Range & Double Planetary 34,000-45,000 lbs User Manual

Page 72

Advertising
background image

Air Shifter Valve

(Optional Axle Range Shifter Valve Mounted on Gear Shift Lever).

CAUTION:

AIR SUPPLY TO

VALVE MUST BE SHUT OFF BEã

FORE THE VALVE IS SERVICED.

The shifter valve can be disassem-

bled for service without removing

the assembly from the gear shift

lever.

1.

Remove screw from cover,

then lift off cover and remove

shifter knob, knob spring, shifter

plate, "O" ring guide and "O"

ring from valve housing,

2.

If housing requires replace-

ment, disconnect air lines, loosen

jam nut, then unscrew housing

from shift lever.

Inspection and Lubrication

Each 50,000 miles, disassemble,

inspect and clean, then lubricate

moving parts with barium-base

grease. No other type lubricant

should be used.

Assemble and Install Valve

1.

If housing was removed, install jam nut on shift lever. Thread housing

on shift lever and tighten jam nut. Connect air lines. Air shift valve knob

should be positioned at 9:00 o'clock. Lubricate moving parts with barium-

base grease during assembly.

2.

Place shifter plate in mounting

3.

Pre-assemble guide and "O"

position on valve housing.

ring, then place this assembly in

mounting position in shifter plate.

4.

Hold shifter plate in position

with one hand, then install spring

and shifter knob. Install cover and

fasten with screw.

73

Advertising