Using the TROY Port Monitor

Security Printing Solutions User’s Guide -- Document #50-70376-001 Rev. D

6-9

Security Tab
(cont.)

Alternate Escape Sequence – (used only for legacy application compatibility) enter the alternate ASCII character
number (0-255) to use as a replacement for the ASCII character 27 (escape character) in the PCL 5 data stream
sent to the printer. Press the Alt key and enter the ASCII character number.

Enable MICR Mode – check this box to enable MICR mode when printing MICR documents.

HP Job Password – (used only for legacy TROY
printers) enter the password (0-65535) that
matches the job password (PJL command) set in
the TROY printer by the administrator.

Automatic Page Rotation – when printing checks
with the MICR line at the bottom of the check
paper, check this box to rotate the page image 180
degrees to print the MICR line at the top of the
page, ensuring accurate MICR line placement.

TROYmark

– select Disable for no background

image on the check or select either Light,
Medium, or Dark to use a pre-defined density
level for the background image, or select Custom
to use a custom density level that best suits the
design of your check.

Inclusion and Exclusion Regions – enter the
appropriate “X” (horizontal) and “Y” (vertical)
offset numerical values to define the top-left
starting point of the inclusion region and the
exclusion region(s), and then enter the width and
height numerical values to define the bottom-right
ending point of the inclusion and the exclusion
region(s) for placement of the TROYmark

background image and exclusion areas. Click on
Test to print a sample page to verify the
inclusion/exclusion region placement on the
check. Make adjustments to the numerical values
as needed. Each increment in the numeric value equals 1/600th of an inch.