6-20

Procedure #5: Diagnosing GPS-related problems

If you do not see a GPS, DGPS, or RTK in the upper left-hand corner of the EC Surveyor screen,
you do not have GPS coming in, and no data will be sent out the serial port for logging.

Figure 5.1

Insure your GPS receiver is powered and outputting NMEA strings GGA, and either VTG or RMC
at a 1hz rate; 4800 baud, 8 data bits, no parity, 1 stop bit. Verify that your GPS cable is sending
GPS data through pin 2, pin 5 is ground, and no other pins have signal or power on them. The
most common issue is hz rate. If the GPS has been used for lightbar guidance it may have been
set to a 5 or 10 hz rate. It will need to be changed to 1 hz in order for the EC Surveyor to accept it.

Shown below is a Troubleshooting tree for diagnosing GPS signal problems. It is not meant to
replace your GPS receiver user manual

—it merely shows how to determine if your receiver is

sending the GPS signal that the EC Surveyor needs.

Figure 5.2