61

Technical data

Materials

Housing

PBT (Valox) or Aluminium

Process connection

- flange version

Alu or PP

- swivelling holder and thread

galvanized steel

Transducer

- VEGASON 54

PA (1.4301 with StEx)

- VEGASON 55, 56

UP

Transducer diaphragm

- VEGASON 54

1.4571

- VEGASON 55

Alu/PE foam

- VEGASON 56

Alu/PTFE non-stick coating

Transducer cable (cable cover)

- VEGASON 54, 55

PUR (1.1082)

- VEGASON 56

silicone (1.1083)

Weight (depending on the housing materials used)

VEGASON 54

- Version A

5.6 … 10.7 kg

- Version B

6.9 … 9.7 kg

- Version C

7.5 … 10.5 kg

- Version D

4.7 … 6.9 kg

VEGASON 55

- Version A

8.0 … 13.3 kg

- Version B

8.7 … 10.3 kg

- Version C

9.2 … 11.1 kg

- Version D

6.5 … 7.5 kg

VEGASON 56

- Version A

7.3 … 11.3 kg

- Version B

8.7 … 10.3 kg

- Version C

9.3 … 11.1 kg

- Version D

6.5 … 7.5 kg

CE conformity

VEGASON series 50 ultrasonic sensors meet the protective regulations of EMC
(89/336/EWG), NSR (73/23/EWG) and R & TTE directive (1999/5/EC).
Conformity has been judged acc. to the following standardst:

EN 300 683 - 1: 1997
EN 300 440 - 1: 1995
I-ETS 300-440
Expert opinion No. 0043052-01/SEE, Notified
Body No. 0499

EMC

Emission/Susceptibility

EN 61 326: 1997/A1: 1998

ATEX

EN 50 020: 1994
EN 50 018: 1994
EN 50 014: 1997

NSR

EN 61 010 - 1: 1993