6 technical data of the sensors – VEGA VEGASON 83 … 87 ECHOFOX User Manual

Page 11

Advertising
background image

VEGASON 83 … 87

11

2 Product description

2.6

Technical data of the sensors

2.6.1 VEGASON 83 … 87 FV, 84 … 87 FV StEx

VEGASON 83 … 87 GV, 84 … 87 GV StEx

Approvals

see section 2.11 Approvals

Power supply

via signal conditioning instrument

VEGAMET … with digital transmission of measuring data

via processing system

VEGALOG 571 with EV-input cards

Operating voltage

max. 36 V DC

Power consumption

max. 200 mA

Measuring range

VEGASON

83 FV

83 GV

84 …

85 …

87 …

Min. distance for

liquids and
solids

granulation

5 mm 0,7 m

0,5 m

0,7 m

1,0 m

0,4 m

granulation

5 mm 0,8 m

0,6 m

1,0 m

1,2 m

0,4 m

Max. distance dependent on product and process

10 m

10 m

20 m

30 m

60 m

Measuring data

Measuring resolution

1 mm

1 mm

1 mm

1 mm

1 mm

Measuring frequency

33 kHz

33 kHz

22 kHz

16 kHz

16 kHz

Measuring rate

0,6 sec.

0,6 sec.

0,7 sec.

1,0 sec.

1,5 sec.

Radiation angle related to –3 dB

12

°

12

°

12

°

15

°

3,5

°

Error limits

Linearity error relating to the adjustment

< 0,1 % of measuring range

Temperature error of the electronics

0,015 %/10 K of measuring range

Materials

VEGASON

FV

GV

StEx

Housing and cover of electronics

PBT

PBT

PBT

Flange

PPh

–––

St 37 galv. or Alu

Transducer housing

PVDF

PVDF

PVDF

Impedance adapter

PE

PE

PE

Transducer fixing tube

- Type83

–––

PVDF

St 37 galvanized

- Type 84 and 85

–––

RCH 1000

St 37 galvanized

- Type 87

–––

St 37 galvanized

St 37 galvanized

Dimensions and weights

Flange size

- Type 83

DN 100 PN 16

–––

DN 100 PN 16

- Type 84 and 85

DN 150 PN 16

–––

DN 150 PN 16

- Type 87

ш 450

–––

ш 450

Thread of the fixing tube

–––

G 1 A

–––

Total weight of sensors

- Type 83 … 85

appr. 6 kg

appr. 6 kg

appr. 6 kg

- Type 87

appr. 12 kg

appr. 12 kg

appr. 12 kg

Temperature reaction

VEGASON … StEx-version
At an ambient temperature

40

°

C the max. temperature to be adjusted

- on the transducer in Zone 10

45

°

C is reached and

- on the housing (electronics) in Zone 11

55

°

C is reached

Advertising