VEGA VEGASON 83 … 87 ECHOFOX User Manual

Page 13

Advertising
background image

VEGASON 83 … 87

13

2 Product description

2.6.2 VEGASON 83 and 84 Ex, Ex0

VEGASON 83 and 84 Ex B, Ex0 B

Approvals

see section 2.11 Approvals

Power supply

via separator

Type 146 or VEGATRENN 546

Supply via

2 intrinsically safe circuits of category ib IIB

Flame proofing

EEx de ia IIB T6 (see also section 2.11)

Measuring range

VEGASON

83

84

Min. distance of liquids

0,7 m

1,1 m

Max. distance dependent on product and process

10 m

20 m

Measuring data

Measuring resolution

1 mm

1 mm

Measuring frequency

33 kHz

22 kHz

Measuring rate

1,1 sec.

1,5 sec

Radiation angle related to –3 dB

12

°

12

°

Error limits

Linearity error relating to the adjustment

< 0,1 % of measuring range

Temperature error of the electronics

0,015 %/10 K of measuring range

Materials

Housing of electronics

1.4305

Flange

1.4305

Diaphragm

1.4531

Flange sealing

Viton

Dimensions and weights

Flange size

- Type 83

DN 100 PN 16

- Type 84

DN 150 PN 16

Total weight of the sensors

at DN 100 approx. 17 kg
at DN 150 approx. 21 kg

Ambient conditions

Max. permissible ambient temperature
- on the transducer

+80

°

C

- on the housing (electronics)

+60

°

C

Storage and transport temperature

-20

°

C … +80

°

C

Protection

IP 67

Max. vessel pressure

- Type 83

2 bar

- Type 84

1 bar

Vessel pressures and ambient temperature
under Ex-conditions

see respective conformity certificate

Connection line

Sensor … separator

2 x 2 pole

Resistance per conductor

max. 7,5 Ohm

Temperature sensor and its connection

integrated int he respective sensor

Electrical connection

Terminals for the connection line

max. 1,5 mm

2

Terminals for earth connection

max. 4,0 mm

2

Cable entry

1 x Pg 13,5

Advertising