VEGA VEGASON 83 … 87 ECHOFOX User Manual
Page 13
VEGASON 83 … 87
13
2 Product description
2.6.2 VEGASON 83 and 84 Ex, Ex0
VEGASON 83 and 84 Ex B, Ex0 B
Approvals
see section 2.11 Approvals
Power supply
via separator
Type 146 or VEGATRENN 546
Supply via
2 intrinsically safe circuits of category ib IIB
Flame proofing
EEx de ia IIB T6 (see also section 2.11)
Measuring range
VEGASON
83
84
Min. distance of liquids
0,7 m
1,1 m
Max. distance dependent on product and process
10 m
20 m
Measuring data
Measuring resolution
1 mm
1 mm
Measuring frequency
33 kHz
22 kHz
Measuring rate
1,1 sec.
1,5 sec
Radiation angle related to –3 dB
12
°
12
°
Error limits
Linearity error relating to the adjustment
< 0,1 % of measuring range
Temperature error of the electronics
0,015 %/10 K of measuring range
Materials
Housing of electronics
1.4305
Flange
1.4305
Diaphragm
1.4531
Flange sealing
Viton
Dimensions and weights
Flange size
- Type 83
DN 100 PN 16
- Type 84
DN 150 PN 16
Total weight of the sensors
at DN 100 approx. 17 kg
at DN 150 approx. 21 kg
Ambient conditions
Max. permissible ambient temperature
- on the transducer
+80
°
C
- on the housing (electronics)
+60
°
C
Storage and transport temperature
-20
°
C … +80
°
C
Protection
IP 67
Max. vessel pressure
- Type 83
2 bar
- Type 84
1 bar
Vessel pressures and ambient temperature
under Ex-conditions
see respective conformity certificate
Connection line
Sensor … separator
2 x 2 pole
Resistance per conductor
max. 7,5 Ohm
Temperature sensor and its connection
integrated int he respective sensor
Electrical connection
Terminals for the connection line
max. 1,5 mm
2
Terminals for earth connection
max. 4,0 mm
2
Cable entry
1 x Pg 13,5