3environment – VEGA VEGASON 83 … 87 ECHOFOX User Manual

Page 23

Advertising
background image

VEGASON 83 … 87

23

3 Environment

3

Environment

3.1

Installation recommendations
relating to liquid tank / vessels

Installation under normal conditions

Flange version
Mounting on a very short, generally on a DIN-socket piece
available on the tank.

The max. filling of the tank depends on the min. distance
of the respective sensor or compact instrument.

Installation under special conditions

If the min. distance of the sensor is decreased, mounting
on a socket piece is necessary.

Generally the diameter of the socket piece should be as
large as possible and the socket length should be as short
as possible.

Min. distance

Separate version
Mounting of the transducer in a very small hole (ø 35 mm)
in the tank ceiling. The mounting procedure can be
provided via an available access hatch.

The max. filling of the tank depends on the min. distance
of the respective sensor or compact instrument.

Min. distance

ø socket piece

Length of socket piece

ø

L

Tube length L to tube diameter ø

VEGASON

83

84

85

87

Socket piece-ø

100

400

–––

–––

–––

150

400

300

300

–––

200

500

400

400

–––

250

600

500

500

–––

300

–––

600

600

–––

350

–––

700

700

350

See the following schedule as general tube relating to the
dimensioning of the socket piece length to socket piece
diameter.

~45

°

Min. distance