VEGA VEGASON 83 … 87 ECHOFOX User Manual

Page 12

Advertising
background image

VEGASON 83 … 87

12

2 Product description

Ambient conditions

VEGASON

FV

GV

StEx

Ambient temperature related to
- transducer in Zone 10

-20

°

C … +80

°

C

-20

°

C … +80

°

C

-20

°

C … +75

°

C

- housing (electronics) in Zone 11

-20

°

C … +60

°

C

-20

°

C … +60

°

C

-20

°

C … +60

°

C

Storage and transport temperature

-20

°

C … +80

°

C

-20

°

C … +80

°

C

-20

°

C … +80

°

C

Protection
- of transducer

IP 67

IP 67

IP 65

- the housing (electronics) generally

IP 67

IP 67

IP 65

certified
- transducer

–––

–––

IP 65

- housing

–––

–––

IP 54

Overvoltage class

III

III

III

Protection class

II

II

II

Max. vessel pressure related to

- Type 83

0,5 bar

1,0 bar

–––

- Type 84 and 85

0,5 bar

0,5 bar

0,5 bar

- Type 87

0,3 bar

0,5 bar

0,5 bar

Connection line

VEGASON … FV-version
Sensor to signal conditioning instrument /
processing system

2 pole, maximal 20 Ohm/line

VEGASON … GV-version
Transducer to sensor electronics

- Type 83 … 85

standard coax cable type RG 58
standard length 5 m
max. length 300 m

- Type 87

4 x 0,38 mm

2

, 1 screened wire

standard length 5 m, max. length 35 m
cable diameter 8 mm

Sensor electronics to signal conditioning
instrument / processing system

2 pole, max. 20 Ohm/line

Temperature sensor

each integrated in the transmitter
with GV-version via connected connection line
above connection line

Electrical connection

Terminals for the connection lines

for max. 1,5 mm

2

Terminals for the earth connection

for max. 4,0 mm

2

Cable entry

1 x Pg 13,5 for all FV-versions
2 x Pg 13,5 for all GV-versions

Advertising