17

2 Product description

Ambient conditions

VEGASON

FK

GK

StEx

Ambient temperatures related to
- transducer in Zone 10

-20

°

C … +80

°

C

-20

°

C … +80

°

C

-20

°

C … +75

°

C

- housing (electronics) in Zone 11

-20

°

C … +60

°

C

-20

°

C … +60

°

C

-20

°

C … +60

°

C

Storage and transport temperature

-20

°

C … +80

°

C

-20

°

C … +80

°

C

-20

°

C … +80

°

C

Protection
- of the transducer

IP 67

IP 67

IP 65

- of the housing (electronics) generally

IP 67

IP 67

IP 65

certified
- transducer

–––

–––

IP 65

- housing

–––

–––

IP 54

Overvoltage class

III

III

III

Protection class

II

II

II

Max. vessel pressure related to

- Type 83

0,5 bar

1,0 bar

–––

- Type 84 and 85

0,5 bar

0,5 bar

0,5 bar

- Type 87

0,3 bar

0,5 bar

0,5 bar

Connection line

VEGASON … FK-versions
Power supply

2/3 pole, standard cable

VEGASON … GK-versions
Transducer to sensor electronics

- Type 83 … 85

standard coax cable type RG 58
standard length 5 m
max. length 300 m

- Type 87

4 x 0,38 mm

2

, 1 screened wire

standard length 5 m, max. length 35 m
cable diameter 8 mm

Temperature sensor

each integrated in the transmitter
with GK-version connected via above
connection line

Electrical connection

Terminals for the connection lines