3 mounting preparations – parabolic antenna, 3 mounting preparations - parabolic antenna – VEGA VEGAPULS 62 (≥ 2.0.0 - ≤ 3.8) 4 … 20 mA_HART four-wire User Manual

Page 15

Advertising
background image

Note:
VEGAPULS

62

with rinsing air connection or antenna extension is

provided with a notch on the antenna socket. This notch must
correspond to the marking on the hexagon of the process fitting (the
marking specifies the position of the polarisation level of the radar
signal).

3

4

1

2

Fig. 5: Dismounting horn antenna

1

Marking

2

Notch

3

Hexagon screws on the antenna socket

4

Antenna

4.3 Mounting preparations - Parabolic antenna

Information:
T

his information applies only to special versions!

VEGAPULS

62

is also available in versions where the antenna has a

diameter larger than the process fitting (thread, flange). With such
versions the antenna must be disconnected from the process fitting
before mounting. Proceed as follows:

1

C

lamp VEGAPULS 62 with the flange, e.g. in a bench vice

2

H

old the connection piece (3) with a wrench SW 22 on the

attenings

3

U

nscrew the locknut (2) with SW 36 against the antenna

4

L

oosen compression nut (1) with a wrench SW 41 completely in

the direction of the antenna

5

R

emove the parabolic antenna (4) axially

6

M

ount sensor flange to the adapter flange and clamp it

VEGAPULS

62 • 4 … 20

mA/HART four-wire

15

4 M

ounting

28440

-EN

-090305

Advertising