10 supplement, 1 technical data, 10 .1 technical data – VEGA VEGABAR 65 Foundation Fieldbus User Manual

Page 52

Advertising
background image

10

Supplement

10

.1 Technical data

General data

Pressure type

Gauge pressure or gauge pressure

Measuring principle

ceramic-capacitive, temperature-compensated iso-
lated system

Communication interface

I

²C bus

Materials and weights

Materials, wetted parts

-

Process fitting

316L

-

Process diaphragm

Hastelloy C276, gold-coated, gold/rhodium-coated

-

Process seal other hygienic fittings

EPDM: Version up to 140 °C (284 °F)
FKM: Version up to 180/200 °C (356/392 °F)

-

Process seal hygienic fitting with com-
pression nut

FEP-O-Seal

-

Seal, process fitting thread G1½ A

Klingersil C-4400

Materials, non-wetted parts

-

Isolating liquid

med. white oil, FDA approved

-

Electronics housing

Plastic PBT (polyester), Alu die-casting powder-
coated, 316L

-

External electronics housing

plastic PBT (Polyester)

-

Socket, wall mounting plate external
electronics housing

plastic PBT (Polyester)

-

Seal between housing socket and wall
mounting plate

TPE (fixed connected)

-

Seal ring, housing cover

NBR (stainless steel housing), silicone (Alu/plastic
housing)

-

Inspection window in housing cover for
indicating and adjustment module

Polycarbonate (UL-746-C listed)

-

Ground terminal

316Ti/316L

-

Connection between IP 68 transmitter
and external electronics housing

PUR, FEP, PE

-

Type plate support with IP 68 version on
cable

PE hard

Weight approx.

0.8 … 8 kg (1.764 … 17.64 lbs), depending on
process fitting

Output variable

Output

-

Signal

digital output signal, Foundation Fieldbus protocol

-

Physical layer

according to IEC 61158-2

52

VEGABAR

65 • Foundation Fieldbus

10 Supplement

28260

-EN

-090522

Advertising