VEGA VEGABAR 64 4 … 20 mA_HART User Manual

Page 58

Advertising
background image

T

hermal change zero signal and output span with absolute pressure measuring range 0.1 bar,

reference temperature 20 °C (68 °F):

-

I

n the compensated temperature range

0 … +100 °C (+32 … +212 °F)

< (0.1 % + 0.1 %

x TD)

-

O

utside the compensated temperature

range

< (0.15 % + 0.15 %

x TD)

A

pplies also to instruments with analogue 4 … 20 mA current output and refers to the set span.

T

hermal change, current output

<

0.15 %

at -40 … +80 °C (-40 … +176 °F)

Long-term stability (similar to DIN 16086, DINV 19259-1 and IEC 60770-1)

A

pplies to digital interfaces (HART, Profibus PA, Foundation Fieldbus) as well as to analogue

current output 4 … 20 mA. Specifications refer to the set span. Turn down (TD) = nominal
measuring range/set span.

L

ong-term drift of the zero signal

< (0.1 %

x TD)/year

Ambient conditions

A

mbient, storage and transport temperature

-40 … +80 °C (-40 … +176 °F)

Process conditions

T

he specifications to the pressure stage and the product temperature are used as an overview.

T

he specifications of the type label are applicable.

P

ressure stage, process fitting

-

T

hread 316L

PN

60

-

T

hread Aluminium

PN

25

-

T

hread PVDF

PN

10

-

H

ygienic fittings 316L

PN

6, PN 10, PN 25, PN 40

-

F

lange 316L

PN

16, PN 40,150

lbs, 300 lbs, 600 lbs

-

F

lange with extension 316L

without PN specification, PN 16, PN 40 or 150 lbs,
300

lbs, 600 lbs

-

F

lange PVDF

PN

16

P

roduct temperature standard version, depending on the meas. cell seal

10)

-

FKM (VP2/A)

-20 … +120 °C (-4 … +248 °F)

-

EPDM (A+P 75.5/KW75F)

-40 … +120 °C (-40 … +248 °F), 1

h: 140 °C/284 °F

cleaning temperature

-

FFKM (K

alrez 6375)

-10 … +120 °C (+14 … +248 °F)

-

FFKM (C

hemraz 535)

-30 … +120 °C (-22 … +248 °F)

P

roduct temperature version with extended temperature range, depending on the meas. cell seal

as well as order specification

-

FKM (VP2/A)

-20 … +150 °C (-4 … +302 °F)

-

EPDM (A+P 75.5/KW75F)

-40 … +150 °C (-40 … +302 °F)

10)

W

ith process fitting PVDF, max. 100 °C (212 °F).

58

VEGABAR

64 • 4 … 20

mA/HART

10 S

upplement

27525

-EN

-081209

Advertising