VEGA VEGABAR 74 4 … 20 mA_HART User Manual

Page 31

Advertising
background image

-

F

T

: T

emperature coefficient (influ-

ence of medium or ambient tem-
perature)

-

F

K

l

: D

eviation

Ambient conditions

A

mbient, storage and transport temperature

-

C

onnection cable PE

-40 … +60 °C (-40 … +140 °F)

-

C

onnection cable PUR, FEP

-40 … +85 °C (-40 … +185 °F)

Process conditions

T

he specifications of the pressure stage are used as an overview. The specifications on the

type plate are applicable.

P

ressure stage, process fitting

-

T

hread 316L

PN

60

-

T

hread Alu

PN

25

-

H

ygienic fittings 316L

PN

10, PN 16, PN 25, PN 40

-

F

lange 316L, flange with extension

316L

PN

40

or 150 lbs, 300 lbs

P

roduct temperature depending on the measuring cell seal

-

FKM (

e.g. Viton)

-20 … +100 °C (-4 … +212 °F)

-

EPDM

-40 … +100 °C (-40 … +212 °F), 1

h: 140 °C/

284 °F

cleaning temperature

-

K

alrez 6375 (FFKM)

-10 … +100 °C (+14 … +212 °F)

-

C

hemraz 535

-30 … +100 °C (-22 … +212 °F)

V

ibration resistance

mechanical vibrations with 4 g and 5 … 100 Hz

8)

S

hock resistance

A

cceleration 100 g/6 ms

9)

Electromechanical data

C

onnection cable

-

C

onfiguration

four wires, one suspension cable, one breather
capillary, screen braiding, metal foil, mantle

-

W

ire cross-section

0.5

mm² (AWG no. 20)

-

wire resistance

<

0.036 O

hm/m (0.011 Ohm/ft)

-

S

tandard length

6

m (19.685 ft)

-

max. length with VEGADIS 12

200

m (656.168 ft)

8)

T

ested according to the regulations of German Lloyd, GL directive 2.

9)

T

ested according to EN 60068-2-27.

S

upplement

VEGABAR

74 - 4 … 20

mA/HART

31

28432

-

EN

-070718

Advertising