3 exchanging the electronics module – VEGA VEGAFLEX 66 (-110…+400°C) Profibus PA User Manual

Page 41

Advertising
background image

?

E

017

l

Adjustment span too small

à Carry out a fresh adjustment and increase the distance

between min. and max. adjustment

?

E

036

l

no operable sensor software

à Carry out a software update or send the instrument for

repair

?

E

042/E043

l

Hardware error, electronics defective

à Exchange instrument or return instrument for repair

?

E

113

l

Communication conflict

à Exchange instrument or return instrument for repair

Depending on the failure reason and measures taken, the
steps described in chapter "Set up" must be carried out again,
if necessary.

8.3 Exchanging the electronics module

If the electronics module is defective, it can be replaced by the
user.

In Ex applications only one oscillator with respective Ex
approval may be used.

If there is no electronics module available on site, one can be
ordered from the agency serving you.

The new oscillator must contain the order data of the sensor.
These can be loaded as follows:

l

At the factory by VEGA

l

Or on site by the user

Information:
When loading on site, first of all the order data must be
downloaded from the Internet (see operating instructions
manual "Oscillator").

Reaction after fault rec-
tification

Preparations

VEGAFLEX

66 • Profibus PA

41

8 Maintenance and fault rectification

32764

-

EN

-080716

Advertising