VEGA VEGAFLEX 66 (-110…+400°C) Profibus PA User Manual
Page 49
Output variable
Output signal
digital output signal, format according to
IEEE-
754
Sensor address
126 (default setting)
Current value
10 mA, ±0.5 mA
Integration time (63 % of the input
variable)
0 … 999 s, adjustable
Step response or adjustment time
≤
250 ms (ti: 0 s, 10 … 90 %)
Accuracy (similar to DIN EN 60770-1)
Reference conditions according to DIN EN 61298-1
-
Temperature
+
18 … +30 °C (+64 … +86 °F)
-
Relative humidity
45 … 75 %
-
Air pressure
860 … 1060 mbar/86 … 106 kPa
(
12.5 … 15.4 psig)
Deviation in characteristics and characteristics
Reference installation conditions
-
Flange size
> DN
100
-
min. distance to installations
>
500 mm (19.69 in)
-
Vessel diameter
1 m (3.281 ft) centrical installaton
-
Medium
Water
Temperature drift (current output)
0.06 %/10 K relating to the max. measuring
range
Accuracy
see diagrams
3 mm
(
1
/
8
")
-3 mm
(-
1
/
8
")
10 mm
(
25
/
64
")
-10 mm
(-
25
/
64
")
0,5 m
(1.6 ft)
0,08 m
(0.26 ft)
6 m
(20 ft)
Fig. 21: Accuracy - Rod version -110 … +400 °C (-166 … +752 °F)
VEGAFLEX
66 • Profibus PA
49
10 Supplement
32764
-
EN
-080716