VEGA MINITRAC 31 4 … 20 mA_HART - four-wire User Manual

Page 76

Advertising
background image

76

11 Supplement

MINITRAC 31 • 4 … 20 mA/HART - four-wire

40447-EN-131119

Ʋ 4 … 20 mA/HART - intrinsically safe

< 300 Ω

Damping (63 % of the input variable)

Automatically

HART output values

Ʋ PV (Primary Value)

Switching status

Ʋ SV (Secondary Value)

Electronics temperature

Output variable - X-ray alarm
Output signals

4 … 20 mA/HART - active; 4 … 20 mA/HART - passive

Range of the output signal

3.8 … 20.5 mA/HART

Terminal voltage passive

9 … 30 V DC

Shortcircuit protection

Available

Potential separation

Available

Signal resolution

0.3 µA

Failure signal current output (adjustable) 22 mA, < 3.6 mA
Max. output current

22 mA

Starting current

≤ 3.6 mA

Load

Ʋ 4 … 20 mA/HART - active

< 500 Ω

Ʋ 4 … 20 mA/HART - intrinsically safe

< 300 Ω

Damping (63 % of the input variable)

Automatically

HART output values

Ʋ PV (Primary Value)

X-ray alarm

Ʋ SV (Secondary Value)

Electronics temperature

Output variable - Real value correction
Output signals

8/16 mA/HART - active; 8/16 mA/HART - passive

Terminal voltage passive

9 … 30 V DC

Shortcircuit protection

Available

Potential separation

Available

Signal resolution

0.3 µA

Failure signal current output (adjustable) 22 mA, < 3.6 mA
Max. output current

22 mA

Starting current

≤ 3.6 mA

Load

Ʋ 4 … 20 mA/HART - active

< 500 Ω

Ʋ 4 … 20 mA/HART - intrinsically safe

< 300 Ω

Damping (63 % of the input variable)

1 … 1200 s, adjustable

HART output values

Ʋ PV (Primary Value)

Switching status

Ʋ SV (Secondary Value)

Electronics temperature

Advertising