VEGA MINITRAC 31 4 … 20 mA_HART - four-wire User Manual

Page 78

Advertising
background image

78

11 Supplement

MINITRAC 31 • 4 … 20 mA/HART - four-wire

40447-EN-131119

Characteristics and performance data
Step response time

5)

≤ 5 s (with damping 1 s)

Ambient conditions
Ambient, storage and transport tempera-

ture

-40 … +60 °C (-40 … +140 °F)

Process conditions
For the process conditions, please also note the specifications on the type label. The lower value

always applies.
Process pressure

Unpressurized

Process temperature (measured on the

detector tube)

-40 … +60 °C (-40 … +140 °F)
With temperatures of more than 60 °C we recommend

the use of water cooling

Vibration resistance

6)

mechanical vibrations up to 1 g in the frequency range

5 … 200 Hz

Electromechanical data - version IP 66/IP 67
Cable entry

Ʋ M20 x 1.5

2 x cable gland M20 x 1.5 (cable: ø 6 … 12 mm), 4 x

blind plug M20 x 1.5
Included: 1 x cable gland M20 x 1.5

Ʋ ½ NPT

5 x closing cap (red) ½ NPT
Included: 3 x cable gland ½ NPT (cable: ø 6 … 12 mm),

4 x blind plug ½ NPT

Spring-loaded terminals for wire cross-section

Ʋ Massive wire, cord

0.2 … 2.5 mm² (AWG 24 … 14)

Ʋ Stranded wire with end sleeve

0.2 … 1.5 mm² (AWG 24 … 16)

Display and adjustment module
Display element

Display with backlight

Measured value indication

Ʋ Number of digits

5

Ʋ Size of digits

W x H = 7 x 13 mm

Adjustment elements

4 keys

Protection rating

Ʋ unassembled

IP 20

Ʋ mounted into the housing without

cover

IP 40

Materials

Ʋ Housing

ABS

5)

Time span after a sudden measuring distance change by max. 0.5 m in liquid applications, max 2 m with bulk

solids applications, until the output signal has taken for the first time 90 % of the final value (IEC 61298-2).

6)

Tested according to the guidelines of German Lloyd, GL directive 2.