4 accessories and replacement parts, 5 corresponding source container – VEGA WEIGHTRAC 31 4 … 20 mA_HART - four-wire User Manual

Page 10

Advertising
background image

10

3 Product description

WEIGHTRAC 31 • 4 … 20 mA/HART - four-wire

42374-EN-131119

3.4 Accessories and replacement parts

The display module PLICSCOM is used for measured value indication

and diagnosis. It can be inserted into the sensor and removed at any

time.

The interface adapter VEGACONNECT enables the connection of

communication-capable instruments to the USB interface of a PC. For

parameter adjustment of these instruments, the adjustment software

PACTware with VEGA-DTM is required.
You can find further information in the operating instructions "Interface

adapter VEGACONNECT" (Document-ID 32628).

VEGADIS 61 is an external display unit for sensors with single cham-

ber housing and Ex-d double chamber housing.
It is suitable for measured value indication and is connected to the

sensor with a four-wire standard cable up to 50 m long.
You can find further information in the operating instructions "VE-

GADIS 61" (Document-ID 27720).

The VEGADIS 62 is suitable for measured value indication of sensors.

It is looped into the 4 … 20 mA/HART signal cable.
You can find further information in the operating instructions "VE-

GADIS 62" (Document-ID 36469).

The electronics module PT30E.XX is a replacement part for radiation-

based sensors WEIGHTRAC 31.
The electronics module can only be exchanged by VEGA service

technician.

If you have ordered WEIGHTRAC 31 without a measuring frame, a

basic mounting set is enclosed with the instrument. It includes every-

thing needed to fasten the measuring tube reliably.

The corresponding measuring frame and mounting accessories can

be ordered optionally.

Use a tachometer for detection of the belt speed. The tachometer can

be connected to the input of the WEIGHTRAC 31.

3.5 Corresponding source container

An isotope in a suitable source container (e.g. SHLD-1) is the prereq-

uisite for a radiation-based measurement setup.
The handling of radioactive substances is regulated by law. The radia-

tion protection rules of the country in which the system is operated

apply first and foremost.
In Germany, for example, the current radiation protection ordinance

(StrlSchV) based on the Atomic Energy Law (AtG) applies.
The following points are important for measurement with radiation-

based methods:

Indicating module

VEGACONNECT

External display and

adjustment unit

External indicating unit

Electronics module

Basic mounting set

Measuring frame for

mounting

Tachometer

Advertising