4 Mounting

WEIGHTRAC 31 • 4 … 20 mA/HART - four-wire

42374-EN-131119

1

2

3

4

5

4

2

6

7

Fig. 4: Mounting of the sensor with the basic mounting set
1 Screws M6 x 120 (4 pcs.)

2 Wedge lock washer M6 Nordlock (8 pcs.)

3 Cover plate (2 pcs.)

4 Clamp collar (4 pcs.) PA

5 Sensor

6 Mounting bracket

7 Nut M6 (4 pcs.)

3. Move the sensor (5) laterally beneath the conveyor belt and place

the sensor in the two clamp collars (4).
Position the measuring width of the sensor below the conveyor

belt as close as possible to the center. Make sure that there is

sufficient distance between sensor and conveyor belt when the

belt is loaded.

4. Place the other two clamp collars (4) according to the illustration

above the clamp collars that are already in place (4).

5. Place a metallic cover plate (3) according to the illustration on

each upper clamp collar (4).

6. Insert the screws (1), each with one wedge lock washer (2),

through the clamp collars (4).

7. Place a wedge lock washer (2) from below on each screw (1) and

screw one nut (7) onto each screw.