4 Mounting

WEIGHTRAC 31 • 4 … 20 mA/HART - four-wire

42374-EN-131119

The mounting of the measuring frame is finished.
Strain the measuring frame

Large measuring frames can deflect when subjected to strong vibra-

tion or strong winds.
Therefore, measuring frames used on conveyor belts with widths over

1600 mm (63 in) should be strained with steel cables.
For this there are two fastening straps on the side of the support stand

of the measuring frame.
Determine the fastening points on your conveyor belt according to the

local conditions.
Provide the straining screws (1) for each cable to ensure reliable

straining of the measuring frame.
Make sure that the measuring frame is perfectly vertical after strain-

ing.

1

Fig. 10: Straining the measuring frame
1 Straining screw

If the max. ambient temperature is exceeded, you must take suitable

measures to protect the instrument against overheating.
You can protect the instrument by providing a suitable insulation

against the heat or mounting the instrument further away from the

heat source.
Make sure these measures are taken into account already in the plan-

ning stage. If you want to carry out such measures later on, contact

our specialists to ensure that the accuracy of the application is not

impaired.
If these measures are not sufficient to maintain the max. ambient

temperature, you could consider using the water cooling system we

offer for WEIGHTRAC 31.

Protection against heat