VEGA VEGABAR 87 Modbus and Levelmaster protocol - Operating Instructions User Manual

Page 60

Advertising
background image

60

10 Supplement

VEGABAR 87 • Modbus and Levelmaster protocol

46297-EN-131107

Interface to the slave sensor
Data transmission

digital (I²C-Bus)

Configuration, connection cable

4-wire, screened

Cable length max.

25 m

Integrated clock
Date format

Day.Month.Year

Time format

12 h/24 h

Time zone Ex factory

CET

Rate deviation max.

10.5 min/year

Measurement electronics temerature
Resolution

1 °C (1.8 °F)

Accuracy

±1 °C (1.8 °F)

Voltage supply
Operating voltage

8 … 30 V DC

Power consumption

< 500 mW

Interpolation protection

Integrated

Potential connections in the instrument
Electronics

Not non-floating

Ground terminal

Galvanically connected with the process fitting

Electrical protective measures

Housing material

Version

IP-protection class

NEMA protection

Plastic

Single chamber

IP 66/IP 67

NEMA 4X/6P

Double chamber

IP 66/IP 67

NEMA 4X

Aluminium

Single chamber

IP 66/IP 68 (0.2 bar)
IP 68 (1 bar)

NEMA 4X/6P
-

Double chamber

IP 66/IP 67
IP 66/IP 68 (0.2 bar)

NEMA 4X
NEMA 4X

Stainless steel, electro-

polished

Single chamber
Single chamber

IP 69K
IP 66/IP 68 (0.2 bar)

-
NEMA 4X/6P

Stainless steel, investment

casting

Single chamber

IP 66/IP 68 (0.2 bar)
IP 68 (1 bar)

NEMA 4X/6P
NEMA 4X

Double chamber

IP 66/IP 67
IP 66/IP 68 (0.2 bar)

NEMA 4X
NEMA 4X

Stainless steel

Transmitter for external

housing

IP 68 (25 bar)

-

Overvoltage category

III

Protection class

II