VEGA VEGAFLEX 82 Modbus and Levelmaster protocol User Manual
Page 30
30
6 Set up with the display and adjustment module
VEGAFLEX 82 • Modbus and Levelmaster protocol
41833-EN-130314
In this menu item you can select the application. You can choose
between metallic oder non-metallic vessels.
Note:
The selection of the application has a considerable influence on all
other menu items. Keep in mind that as you continue with the param-
eter adjustment, individual menu items are only optionally available.
You have the possibility to choose the demonstration mode.This
mode is suitable for test and demonstration purposes. In this mode,
the sensor ignores the logic parameters of the application and reacts
immediately to each change.
In this menu item, you can define the medium type (product).
This menu item is only available if you have selected level measure-
ment under the menu item "Application".
You can choose between the following medium types:
Dielectric con-
stant
Medium type
Examples
> 3
Cereals, flour
All kind of cereals, wheat flour
1.5 … 3
Granules, cement Lime, gypsum, cement
< 1.5
Dusts, wood chips Wood chips, sawdust
In this menu item, you can enter the max. adjustment for the level.
Adjust the requested percentage value with [+] and save with [OK].
Enter the appropriate distance value in m (corresponding to the
percentage value) for the full vessel. The distance refers to the sensor
Setup - Application
Setup - Medium, dielec-
tric constant
Setup - Max. adjustment
Level