9 Diagnostics and service

VEGAFLEX 82 • Modbus and Levelmaster protocol

41833-EN-130314

Information:

Please keep the stated torque so that the max. tensile strength

remains.

The rod or cable of the probe can be shortened individually.

1. Mark the requested length with mounted measuring rod.
2. Cable: Loosen the three pins on the gravity weight

Cable ø 4: 6 hexagon 3
Cable ø 6, cable ø 8: hexagon 4

3. Cable: remove the pins
4. Cable: Pull the cable out of the gravity weight
5. Shorten the cable/rod with a cut-off wheel or metal saw at the

marking. Take note of the specifications in the following illustration

when shortening the cable.

6. Cable: shift the cable into the gravity weight (according to the

drawing)
Plastic coated cable: remove coating according drawing to 70 mm

(2.76 in).

7. Cable: Fasten the cable with three pins, torque 20 Nm

(14.75 lbf in)
Cable ø 4: 7 Nm (5.16 lbf ft)
Cable ø 6, cable ø 8: 20 Nm (14.75 lbf ft)

8. Enter new probe length and then carry out a fresh adjustment

(see "Setup procedure, Carrying out min. adjustment - Carrying

out max. adjustment").

3

1

2

2

A

B

45 mm (1.77")

150 mm (5.91")

70 mm (2.76")

150 mm (5.91")

Fig. 34: Shortening the cable probe
A Gravity weight - cable ø 4 mm

B Gravity weight - cable ø 6 mm

1 Pins

2 Thread M12 for eye-bolt

3 Pins

Shorten cable/rod

Advertising