3 instructions for installation – VEGA VEGAPULS 62 (≥ 2.0.0 - ≥ 4.0.0) 4 … 20 mA_HART - two-wire, approval according to LPR radio standard User Manual

Page 13

Advertising
background image

Note:
The radar sensor with rinsing air connection or antenna extension is
provided with a notch on the antenna socket. This notch must be
aligned with the marking on the process fitting (the marking specifies
the position of the polarisation plane of the radar signal).

3

4

1

2

Fig. 2: Dismounting of the horn antenna

1

Marking of the polarisation plane

2

Marking at the antenna socket

3

Hexagon screws on the antenna socket

4

Antenna

4

.3 Instructions for installation

The emitted radar impulses of the radar sensor are electromagnetic
waves. The polarisation plane is the direction of the electrical wave
component. By turning the instrument in the connection flange or
mounting boss, the polarisation can be used to reduce the effects of
false echoes.

Polarisation plane

VEGAPULS

62 • 4 … 20 mA/HART - two-wire, approval according to LPR radio standard

13

4 Mounting

41718

-EN

-120301

Advertising