VEGA VEGAPULS 62 (≥ 2.0.0 - ≥ 4.0.0) 4 … 20 mA_HART - two-wire, approval according to LPR radio standard User Manual

Page 71

Advertising
background image

Tracking speed of the measuring window
max.

1 m/min

Beam angle

3)

-

Horn antenna ø 75 mm (2.953 in)

10°

-

Horn antenna ø 95 mm (3.74 in)

Emitted HF power

4)

-

Average spectral transmission power
density

-34 dBm/MHz EIRP

-

Max. spectral transmission power den-
sity

+

6 dBm/50 MHz EIRP

-

Max. power density in a distance of 1 m

<

1 µW/cm²

Ambient conditions

Ambient, storage and transport temperature

-40 … +80 °C (-40 … +176 °F)

Process conditions

For the process conditions, please also note the specifications on the type label. The lowest value
always applies.

Seal

Antenna impedance co-
ne

Process temperature (measured on the process
fitting)

FKM (SHS FPM 70C3
GLT)

PTFE

-40 … +130 °C (-40 … +266 °F)

PTFE

5)

-40 … +200 °C (-40 … +392 °F)

PEEK

6)

-40 … +200 °C (-40 … +392 °F)

FFKM (Kalrez 6375)

PTFE

-20 … +130 °C (-4 … +266 °F)

PEEK

-20 … +250 °C (-4 … +482 °F)

FFKM (Kalrez 2035)

PTFE

-15 … +130 °C (5 … +266 °F)

PEEK

-15 … +210 °C (5 … +410 °F)

FFKM (Kalrez 6230)

PTFE

-15 … +130 °C (5 … +266 °F)

PEEK

-15 … +250 °C (5 … +482 °F)

Graphite

Ceramic

-200 … +450 °C (-328 … +842 °F)

Vessel pressure - horn antenna

-

Antenna impedance cone PTFE

-1 … 40 bar (-100 … 4000 kPa/-14.5 … 580 psig)

-

Antenna impedance cone PP

-1 … 3 bar (-100 … 300 kPa/-14.5 … 43.5 psig)

3)

Outside the specified beam angle, the energy of the radar signal has a level
which is reduced by 50 % (-3 dB)

4)

EIRP: Equivalent Isotropic Radiated Power

5)

Not with steam

6)

Not with steam

VEGAPULS

62 • 4 … 20 mA/HART - two-wire, approval according to LPR radio standard

71

11 Supplement

41718

-EN

-120301

Advertising