VEGA VEGAFLEX 82 Profibus PA User Manual

Page 36

Advertising
background image

36

6 Set up with the display and adjustment module

VEGAFLEX 82 • Profibus PA

44220-EN-130910

In this menu item, you can define the type of medium (product).
This menu item is only available if you have selected level measure-

ment under the menu item "Application".

You can choose between the following medium types:

Dielectric con-

stant

Product type

Examples

> 3

Cereals, flour

All kind of cereals, wheat flour

1.5 … 3

Granules, cement Lime, gypsum, cement

< 1.5

Dusts, wood chips Wood chips, sawdust

In this menu item, you can enter the max. adjustment for the level.

Adjust the requested percentage value with [+] and store with [OK].

Enter the appropriate distance value in m (corresponding to the

percentage value) for the full vessel. The distance refers to the sensor

reference plane (seal surface of the process fitting). Keep in mind that

the max. level must lie below the dead band.

In this menu item, you can enter the min. adjustment for the level.

Adjust the requested percentage value with [+] and store with [OK].

Setup - Medium, dielec-

tric constant

Setup - Max. adjustment

Level

Setup - Min. adjustment

Level