4 Mounting

VEGASWING 51 • - contactless electronic switch

41045-EN-130322

Use the recommended cables (see chapter "Connecting to power

supply") and tighten the cable gland.
You can give your VEGASWING 51 additional protection against

moisture penetration by leading the connection cable downward in

front of the cable entry. Rain and condensation water can thus drain

off. This applies mainly to outdoor mounting as well as installation in

areas where high humidity is expected (e.g. through cleaning pro-

cesses) or on cooled or heated vessels.

Fig. 4: Measures against moisture penetration

Do not hold VEGASWING 51 on the tuning fork.

The process fitting must be sealed if there is gauge or low pressure in

the vessel. Before use, check if the seal material is resistant against

the measured product and the process temperature.
The max. permissible pressure is specified in chapter "Technical

data" or on the type label of the sensor.

The vibrating level switch is a measuring instrument and must be

treated accordingly. Bending the vibrating element will destroy the

instrument.

Warning:

The housing must not be used to screw the instrument in! Applying

tightening force can damage internal parts of the housing.
Use the hexagon above the thread for screwing in.

4.2 Instructions for installation

In case of horizontal mounting in adhesive and viscous products, the

surfaces of the tuning fork should be vertical in order to reduce build-

up on the tuning fork. The position of the tuning fork is indicated by a

Moisture

Transport

Pressure/Vacuum

Handling

Adhesive products